On a plant's "Market" tab, a PPA contract can now be assigned to the segment it covers instead of being given a typed power value. The contract takes that segment's panel peak power, a contract covering the whole plant stays on "Whole park", and the tab shows the total capacity assigned.
The "Segments" tab of a plant's components page now groups its inverters into blocks, roofs or sub-parks, each with a name of its own. Each segment adds up the panel and inverter peak power of its inverters, unless a value is set by hand instead.
Until the official quarterly value is published, a running estimate of the Mischpreis (mixed price) used for settlement is calculated from the reBAP and AEP forecasts, covering about 1 month. The official value is recorded once it is published.
Battery storage now has its own page in the plant, showing state of charge, stored energy, usable capacity and the component count as figures, a time-series graph, and a real-time table of the battery components.
In a plant's report, the metrics can now be selected, and the resolution can be switched between daily, weekly and monthly. The report's table and bar chart show the selected metrics at the chosen resolution.
A "Forecast" page now lists a five-day production forecast for every visible plant, filtered by portfolio, searched by name and paged through as a list. Each day shows weather, temperature, wind and an energy figure, plus a power curve under the clear-sky ceiling.
"Deep Analysis" on a plant's components page now runs without a date or analysis mode to choose. It looks back over the last 90 days of weather, picks up to seven mostly clear days, and works out orientation, tilt and panel count for every string from them.
The string list now flags only the strings that need review: ones where neither configuration nor measurement says what is installed, ones where measurement contradicts configuration, and ones found disconnected. "Review" shows configured and measured values side by side, and "Mark as reviewed" clears a flag until the next analysis finds it again.
The data logger wizard now sets up Fronius Datamanager and Datalogger devices, reading every inverter and an optional sensor card from the device itself.
On a plant's components page, several inverters — or all inverters of the plant — can now be selected to assign their model datasheet or show hidden ones in one step. Where a datasheet is attached, the model name in the inverter, string and battery tables opens it.
A WireGuard remote-access server created on a plant now has "Require a pre-shared key" on by default, and the connected site receives an extra generated key alongside its keypair, shown once right after creation. For an existing connection, "Include a pre-shared key" adds, renews or removes the key when its configuration is regenerated.
Starting a network scan on a plant's networking page now opens a dialog where "Scan range (optional)" limits the scan to part of the network and "Overwrite existing names" replaces device names with the latest analysis. Found devices appear in the table while the scan runs, filling in as they are identified.
A QReader data logger can now be set up by mapping its values. The "Map values" step lists every value the device sends for matching to a known measurement, and the "Dry run" step then shows which measurements the mapping produces before saving.
A running deep analysis now shows each step, from production and weather data through strings, combiner boxes, inverters and feed-in meters, with the estimated time left. "Abort" stops it and keeps the results found so far, and at the start a "Clean re-analysis" can be chosen instead of the saved configuration.
Curtailment losses are now calculated separately from the irradiation sensor, from satellite data and from weather data, with a live preview that follows a curtailment within minutes. A flat-rate method (Pauschalbilanzierung), the third German Redispatch 2.0 accounting method, holds the grid power measured before the curtailment as its reference. Plants receive this with their next agent update.