Skip to content

July 2026

Changes released in July 2026.

Open in the full timeline

AgentImprovements and fixesAlerts & events

Plants no longer report a working network connection as offline.

  • An event about a plant's connection now says in words why it opened and what ended it.
  • On large plants, expected production no longer stalls or counts energy twice after the on-site agent restarts.
mirox-agents 3.1.145 – 3.1.147mirox 2.15.73 – 2.15.79
Read more in the documentationActivity
AgentImprovements and fixesAlerts & events

The on-site analysis now reports a string as defective, not an outage. Open string investigations now close after three days without usable data.

  • In the on-site analysis, a producing string below its neighbours on three sunny days is reported as defective.
  • A stuck reading no longer raises a "Measurement conflict" in the on-site analysis.
  • An event for a defective string names the inverter, combiner box and string it concerns.
  • A gradually failing meter no longer appears as an outage in the on-site analysis.
mirox-agents 3.1.140mirox 2.15.32 – 2.15.35
Read more in the documentationComponents
AgentFeatureAlerts & events

A component that measures wrong no longer shows as an outage

Once a day, an inverter's energy is compared with the sum of its combiner boxes, and a combiner box's with the sum of its strings. A component that reads zero while the comparison shows it produced now shows "Measurement conflict" instead of "Outage". Plants receive this with their next agent update.

mirox-agents 3.1.135 – 3.1.138mirox 2.15.21 – 2.15.31
AgentFeatureAlerts & events

Strings that stopped producing are told apart from shaded strings

A string that produces nothing now raises a notice of its own. While the cause is still open it shows as "Investigation" and still counts as producing, becoming an "Outage" once the evidence confirms it or closing when shading explains it. Plants receive this with their next agent update.

mirox 2.14.224 – 2.14.228mirox-agents 3.1.130
AgentFeatureAlerts & events

Plants now report an inverter that has stopped producing

The on-site agent now raises a "Component production outage" event on the "Activity" page when an inverter stops producing. The event appears after three five-minute windows with no output, only in daylight when snow, fog or curtailment does not explain it, and closes once production resumes. Plants receive this with their next agent update.

mirox 2.14.185 – 2.14.194mirox-agents 3.1.124
Read more in the documentationActivity