September 2026
Changes released in September 2026.
A plant controller can now be added as a data logger
A plant controller can now be added as a data logger, reading the grid operator's active-power setpoint as a percentage of installed capacity or the plant's irradiance sensor. Plants receive this with their next agent update.
A data logger's web interface opened through the plant no longer stops after loading its files. The web interface stays open after the files load.
A Meier-NT ADL-MX data logger can now be added
A Meier-NT ADL-MXmini or ADL-MXSpro data logger can now be added and reads the Power-One / ABB Aurora inverters and Si irradiance sensor behind it: power, voltages, currents, temperatures, irradiation, wind speed, daily and total energy, and each inverter's reported operating state. Plants receive this with their next agent update.
A data logger's serial number is now recorded even when it reconnects late after a restart on site.
Bachmann SPPC and mtu EnergyPack now serve as data loggers
A Bachmann SPPC park controller and an mtu EnergyPack battery can now be added as data loggers, the SPPC reading the grid connection point and the grid operator's and direct marketer's limits, the EnergyPack its state of charge, health, stored energy and power limits, with the next agent update.
Each Janitza meter can now be assigned what it reads
At a plant with a battery behind its grid connection point, each Janitza meter can now be assigned what it reads: the grid connection point, the PV feeder or the battery feeder. PV and battery readings then stay separate from the plant's grid figures, with the next agent update.
A day fetched again from a Janitza meter that records every minute now includes the evening. Before, the day broke off in the afternoon.
A wind plant without a feed-in meter now gets its production from the turbines' lifetime energy counters. It no longer raises a fault for the missing meter.
- A battery's control signal now reads zero on its chart while the direct marketer is connected and asking for nothing.
- A battery plant's settlement no longer drops quarter-hours after each restart of the on-site data collection.
Inverters behind a data logger are read again after a missed reply. Wind turbines and battery modules no longer read as offline for most of the day.
- An inverter behind a data logger is read again after a missed reply, instead of dropping out of the data.
- Wind turbines and battery modules no longer read as offline for most of the day while their connection is checked every 30 minutes.
- A plant's mean irradiation no longer includes a reading higher than the sun can deliver.
Vestas wind turbines are now read through VestasOnline
A Vestas VestasOnline SCADA server can now be added as a data logger, and every turbine behind it is read — power, wind and its lifetime energy counter — and listed on the wind plant's "Turbines" page. Plants receive this with their next agent update.
A SEG HighPROTEC relay can now be added as a data logger
A SEG HighPROTEC relay (MCA4 and its siblings) can now be added as a data logger and reads a battery unit's AC side: power, energy counters and trip alarms.
Linyang battery alarms name their condition, Phoenix Contact WebVisit park controllers report their limits and setpoints, and blue'Log loggers stay connected at plants with many strings and sensors.
- Alarms from Linyang containers now name the condition, such as a charge over-temperature, instead of only an alarm level.
- A Phoenix Contact park controller with a WebVisit interface now reports grid and marketer limits, and the setpoints applied.
- blue'Log loggers no longer drop in and out at plants with many strings and sensors.
Expected power is worked out again through stretches where irradiation readings were lost, and Huawei inverters now report model, firmware and rated power.
- Irradiation sensors are no longer reported as sending nothing for hours at a time, and expected power and performance ratio are worked out again.
- Huawei inverters now report their manufacturer, model, firmware version and rated power in their component details.