Skip to content

Changelog

Every change to Mirox, grouped by month. Filter by group or by kind of change.

Clear filters

November 20261

AgentFeatureMajorData collection

A plant controller can now be added as a data logger

A plant controller can now be added as a data logger, with the on-site agent reading the power, energy, operating state, string positions and fault codes of the plant's string inverters. Plants receive this with their next agent update.

mirox 2.15.875 – 2.15.881mirox-agents 3.2.258 – 3.2.264

October 20263

AgentFeatureMajorData collection

An inverter can now be added as a data logger

An inverter can now be added as a data logger, reading its live output, energy, status and alarm codes, and backfilling its day curve from the inverter's web interface at 15-minute steps. Plants receive this with their next agent update.

mirox 2.15.646 – 2.15.652mirox-agents 3.2.160 – 3.2.161
AgentFeatureMajorData collection

A wind plant's SCADA can now be added as a data logger

A wind plant's SCADA can now be added as a data logger, reading each turbine's production, its stop commands with their cause, the grid operator or the direct marketer, and the grid operator's setpoint. Plants receive this with their next agent update.

mirox 2.15.614 – 2.15.619mirox-agents 3.2.144
AgentFeatureMajorData collection

A power quality analyzer can now be added as a feed-in meter

A power quality analyzer can now be added as a feed-in meter and reads the grid, the PV feeder or the battery feeder. Plants receive this with their next agent update.

mirox 2.15.587 – 2.15.592mirox-agents 3.2.131

September 20266

AgentFeatureMajorData collection

A plant controller can now be added as a data logger

A plant controller can now be added as a data logger, reading the grid operator's active-power setpoint as a percentage of installed capacity or the plant's irradiance sensor. Plants receive this with their next agent update.

mirox-agents 3.2.120 – 3.2.123mirox 2.15.570 – 2.15.571
AgentFeatureMajorData collection

A Meier-NT ADL-MX data logger can now be added

A Meier-NT ADL-MXmini or ADL-MXSpro data logger can now be added and reads the Power-One / ABB Aurora inverters and Si irradiance sensor behind it: power, voltages, currents, temperatures, irradiation, wind speed, daily and total energy, and each inverter's reported operating state. Plants receive this with their next agent update.

mirox 2.15.497 – 2.15.503mirox-agents 3.2.87 – 3.2.91
Read more in the documentationData loggersInverter status codes
AgentFeatureMajorData collection

Bachmann SPPC and mtu EnergyPack now serve as data loggers

A Bachmann SPPC park controller and an mtu EnergyPack battery can now be added as data loggers, the SPPC reading the grid connection point and the grid operator's and direct marketer's limits, the EnergyPack its state of charge, health, stored energy and power limits, with the next agent update.

mirox 2.15.486 – 2.15.493mirox-agents 3.2.76 – 3.2.82
Read more in the documentationData loggers
AgentFeatureData collection

Each Janitza meter can now be assigned what it reads

At a plant with a battery behind its grid connection point, each Janitza meter can now be assigned what it reads: the grid connection point, the PV feeder or the battery feeder. PV and battery readings then stay separate from the plant's grid figures, with the next agent update.

mirox 2.15.486 – 2.15.493mirox-agents 3.2.76 – 3.2.82
Read more in the documentationData loggers
AgentFeatureMajorData collection

Vestas wind turbines are now read through VestasOnline

A Vestas VestasOnline SCADA server can now be added as a data logger, and every turbine behind it is read — power, wind and its lifetime energy counter — and listed on the wind plant's "Turbines" page. Plants receive this with their next agent update.

mirox 2.15.428 – 2.15.442mirox-agents 3.2.32 – 3.2.41
Read more in the documentationData loggers

August 20267

AgentFeatureMajorData collection

Huawei battery storage is now read down to its cells

A Huawei SmartLogger with a LUNA2000 battery behind it now reports the whole storage: its converters, the container, its racks, packs and cells, with power, charge and discharge limits, state of charge and cell state of health. Plants receive this with their next agent update.

mirox-agents 3.1.416 – 3.1.417mirox 2.15.361 – 2.15.366
AgentFeatureMajorData collection

Phoenix Contact AXL controllers can now be added as data loggers

A Phoenix Contact AXL controller can now be added as a data logger, reading every combiner box and string, the grid meter with its lifetime feed-in reading, and the irradiation and temperature sensors every 60 seconds. Plants receive this with their next agent update.

mirox 2.15.340 – 2.15.352mirox-agents 3.1.403 – 3.1.412
Read more in the documentationData loggers
AgentFeatureData collection

An Elsist DLMS concentrator can now be added as a data logger

An Elsist SlimLine DLMS concentrator can now be added as a data logger, reading a Landis+Gyr feed-in meter through it: grid power plus the lifetime feed-in and consumption counters, at the meter's own resolution. Plants receive this with their next agent update.

mirox 2.15.340 – 2.15.352mirox-agents 3.1.403 – 3.1.412
Read more in the documentationData loggers
AgentFeatureMajorData collection

A Solar-Log data logger can now be added with only its address

A Solar-Log data logger can now be added like any other, with only its address and, where the logger has one, its user password, after which every inverter, meter and sensor it lists is read, whatever its make.

mirox 2.15.190 – 2.15.197mirox-agents 3.1.259 – 3.1.276
Read more in the documentationData loggers
AgentFeatureMajorData collection

A new data logger now fills in the history it still holds

When a Solar-Log data logger or a Janitza meter is added, the devices behind it that are new to Mirox bring in the readings they still hold, up to two years back. This happens once, in the background, and plants receive it with their next agent update.

mirox 2.15.190 – 2.15.197mirox-agents 3.1.259 – 3.1.276
Read more in the documentationData loggers
AgentFeatureMajorData collection

An SMA Sunny Central plant now comes in from one address

An SMA Sunny Central plant can now be added with "SMA Sunny Central" as the data logger and the address of its SC-COM gateway, behind which its inverter, the string monitor control and every string monitor are found. Plants receive this with their next agent update.

mirox 2.15.160 – 2.15.165mirox-agents 3.1.220 – 3.1.226

May 20262