FixMajorWeb appCurtailment & grid limits
Saving a market option no longer switches off inverter clipping
Saving any option in a plant's market settings no longer sets inverter clipping to be ignored. Since 1 June, plants where that happened showed too much curtailment energy and a compensation calculated from it that was too high as well.
- Only plants whose market settings were saved at least once are affected, and figures already sent stay unchanged.
- On plants where market settings were never saved, clipping was always counted.
- Clipping can still be set to ignored in the plant's market settings.
Shipped withmirox 2.14.71 – 2.14.74