FixMinorAgentAlerts & events
An inverter the data logger cannot read is no longer called faulty
A plant no longer opens an "Inverter device fault" when its data logger reports it cannot read an inverter and no readings arrive. A low-priority "Logger cannot reach inverter" entry opens instead and becomes "Inverter not communicating" after an hour of daylight, and plants receive this with their next agent update.
- The entry names the data logger and how many of its inverters cannot be read.
- It sends no notification and leaves the inverter's status unchanged.
- It closes as soon as the logger reads the inverter again and readings arrive.
- A fault that an inverter or a battery reports about itself is unchanged.
Shipped withmirox 2.15.447 – 2.15.456mirox-agents 3.2.50 – 3.2.51
Read more in the documentationInverter events