The readiness timeline's official-price row no longer shows July as overdue. July's settlement now uses the official price, and issued figures keep their value.
The "Reports" page now shows data readiness in four rows, monitoring, satellite, settled curtailment and official prices. Publishing a report lists non-final metrics with "Regenerate first" or "Publish anyway", and a recomputed settled month reads "Out of date".
The raw curtailment columns of a wind plant settled as "Spitz Wind (power curve)", "Spitz Wind light (reference wind speed)" or "Pauschal Wind (flat rate)" no longer come back empty in exports. They now carry the value.
The "Data Export" tab now offers search, a value mode and a picker down to sensor, turbine and battery-cell level. Export templates offer strict or lenient handling of mixed time steps.
A plant controller can now be added as a data logger, reading the grid operator's active-power setpoint as a percentage of installed capacity or the plant's irradiance sensor. Plants receive this with their next agent update.
An inverter that reports a fault no longer opens its outage only after a curtailment cap or low light has lifted. The event dialog shows which condition it overrode, with the maker's status and text.
The limit a direct marketer states was shown twice, once against the plant controller's own rating. It is now a single figure against the plant's own setpoint, and the plant's curtailed energy is corrected. Plants receive this with their next agent update.
Curtailment and compensation shown close to live no longer show impossible values. A plant whose reference days all fail the plausibility check shows no close-to-live figure, and issued figures keep their value. Plants receive this with their next agent update.
A combiner box behind a data logger previously showed a measured 0 W while its strings carried real current. A missing channel now shows nothing, and an explicit zero still reads as zero. Plants receive this with their next agent update.
In a plant's "Reports" page, the "Outage summary" table lists the month's inverter faults per inverter or per station, with events, duration and energy lost.
The "Outage summary" can show the revenue the lost production would have earned, for members with the accounting permission.
Reports can now be generated in six languages, with Spanish, French, Italian and Portuguese joining English and German.
The component-outage summary no longer marks each inverter's curve on the analysis graph or the production page.
The assistant no longer answers with incoherent text.
On the networking page, a web interface that was detected once is no longer removed when it is not detected again.
A closed outage previously named only the components that recovered last — 7 of 17 silent inverters — and now lists the whole incident. A device fault no longer reopens once the device has withdrawn every fault code, and no longer reads "Live" after an outage takes it over. Plants receive this with their next agent update.
A remote-access (VPN) share no longer closes by itself one hour after the technician's connection comes up. It stays available until the expiry chosen when sharing, or until it is revoked.
The assistant now answers questions about the tunnel, its live status and its log on the shared page of a remote-access share. It sees only that share and never any key material.
A chat opened from the remote-access dialogs or from the metric editor of a report now stays focused on that topic for its whole life. A badge above the message box shows the topic, and the chat offers matching starter questions.
The embedded Grafana dashboards now pick up a member's changed role at the member's next sign-in to the dashboards instead of keeping the old role. An access update after a change in one organization now touches only that organization's portfolios and completes sooner.
A file or folder from a plant or an organization can now be sent to someone outside it, who opens it with a link plus a 6-digit code or a set password, within chosen expiry, visit and download limits. A "Shares" tab now lists every share and what each visitor did.
Remote access to a plant can now be handed to an external technician as a link with its own password, without an account. The page behind the link provides the connection file, shows whether the connection is live, and lets the technician read the server's settings and log and test their own side.
Every plant now has a "Reports" page, on which a template and a period are picked and the report generated and downloaded. While a report is built, its cover and language are set, text added, a chapter renamed or hidden, and the report published to keep its files available to download.
A Meier-NT ADL-MXmini or ADL-MXSpro data logger can now be added and reads the Power-One / ABB Aurora inverters and Si irradiance sensor behind it: power, voltages, currents, temperatures, irradiation, wind speed, daily and total energy, and each inverter's reported operating state. Plants receive this with their next agent update.
On a wind plant's "Market" tab, "Settlement method" now offers "Spitz Wind (power curve)", "Spitz Wind light (reference wind speed)" and "Pauschal Wind (flat rate)". Curtailed energy and its compensation are settled turbine by turbine against each turbine's certified power curve, and the plant figure is their sum.
The reports page now has a "Metrics" tab where an organization defines its own figures from the measurements its plants record, for use in reports and exports. A metric is reported as a plant value or per component, at a chosen finest resolution, and the assistant can write and check one inside the editor.
Wind speed and wind gusts from the weather service were previously recorded in km/h under an m/s label, so the values shown read about 3.6 times too high. They are now recorded in m/s, and values recorded earlier keep the old figure.
A Bachmann SPPC park controller and an mtu EnergyPack battery can now be added as data loggers, the SPPC reading the grid connection point and the grid operator's and direct marketer's limits, the EnergyPack its state of charge, health, stored energy and power limits, with the next agent update.
At a plant with a battery behind its grid connection point, each Janitza meter can now be assigned what it reads: the grid connection point, the PV feeder or the battery feeder. PV and battery readings then stay separate from the plant's grid figures, with the next agent update.
Days that read tens of GWh too high or too low, after a turbine's history was read in again or after a turbine fell silent, now show what the turbines actually produced. The corrected figures appear in the day, week, month and year views and on the day power curve.
A wind plant's "Turbines" page now shows the energy lost to the grid operator, the direct marketer, environmental limits, stop commands and turbine faults. The losses are drawn as stacked areas on the day graph, as segments of the daily, weekly and monthly bars, and as a "Lost in total" figure.
A plant with an alarm system now has an "Alarm system" page, showing each contact's state, its history over 24 hours, 7 or 30 days, and the alarms raised. The intrusion panel and the communication cabinet's UPS, heating and main switch open a plant event while a contact stands and close it when it clears.
A wind plant's "Turbines" page now carries a "Status" column with the maker's own wording for what each turbine reports. Opening a turbine shows a "Status & alarms" section that lists the alarms and warnings it has raised, standing and withdrawn.
A wind plant now has the same "Components" page a solar plant has, with rated power, review cards, tickets and open events for each turbine, plus search, sorting and paging. A datasheet carrying the power curve every analysis measures against can be assigned to several turbines or a whole data logger in one go.
A battery storage can now be added as a data logger, and its converters, battery skids, and racks are then read with power, charge and discharge limits, state of charge, and the grid operator's limits on both charging and feed-in. Plants receive this with their next agent update.
The dashboard's curtailment chart and cards now show the same settled figures as a plant's production page, with quarter-hours not yet settled filled in close to live. Curtailment from before June 2026 is no longer shown on the dashboard because it came from an older calculation, while figures already issued keep their value.
Curtailment and compensation shown before the settlement at plants with battery storage now come from what the inverters produced, not from the feed-in meter behind the battery. They fall wherever the plant was charging or discharging while a limit was in force, and plants receive this with their next agent update. Plants receive this with their next agent update.
A plant no longer opens an "Inverter device fault" when its data logger reports it cannot read an inverter and no readings arrive. A low-priority "Logger cannot reach inverter" entry opens instead and becomes "Inverter not communicating" after an hour of daylight, and plants receive this with their next agent update.
A plant's "Reports" page now assembles a report from chosen sections, with a preview and a PDF or JSON download.
The "Resources" tab on the organization page opens again where it lists a plant with wind turbines.
The monitor and dashboard plant lists now carry a "State" column — "Alert", "Warning", "Communication issue", "Disconnected", "Check" or "Inactive".
The "Turbines" page now shows each turbine's "Utilization (capacity factor)" and, where a datasheet is known, the maker's "Reference curve" with its "Validity band".
A plant set up as a standalone battery plant now opens on "Production", showing what the storage exchanges with the grid and every storage unit in the plant. Where a feed-in meter reports, the page also shows grid power and today's export and import, and without one it shows the units alone.
A wind plant's "Turbines" page now graphs everything the turbines report, one turbine at a time: "Power & wind" draws power and wind speed over time, and "Curve & wind rose" draws the power curve and the wind directions. A selected day now shows its full 24 hours.
A plant set up as a wind plant or a standalone battery plant is no longer measured as if it had panels: it no longer shows an expected-production curve, a clear-sky reference, a performance ratio or curtailment figures. Solar plants are unchanged, and plants receive this with their next agent update.
A Vestas VestasOnline SCADA server can now be added as a data logger, and every turbine behind it is read — power, wind and its lifetime energy counter — and listed on the wind plant's "Turbines" page. Plants receive this with their next agent update.
A SEG HighPROTEC relay (MCA4 and its siblings) can now be added as a data logger and reads a battery unit's AC side: power, energy counters and trip alarms.
The "Import" tab on a plant's "Dataflow" page now takes the ZIP archive from the plant's previous monitoring system and matches its devices to components by serial number or name. The import runs day by day and can be paused, stopped, or have what it wrote deleted.
Curtailment losses previously read too high for any quarter-hour in which the on-site data collection paused: those minutes counted as zero production. Those minutes now count at the rate the measured minutes around them show, and lost energy and compensation fall for such quarter-hours.
On a plant's analysis page, the icons on each station row now count inverters rather than items: one blue wrench for each inverter with open service work. An icon opens a list of those inverters with everything open on each, each entry linking to its inverter.
The round-trip efficiency tile on the battery dashboard now follows the chosen range. The tile shows its own figure for windows of seven days or more, and the day view keeps the trailing week.
mirox 2.15.407 – 2.15.576
Web appImprovements and fixesNetwork & remote access
Devices behind an "SMA Data Manager / Power Manager" or "Sungrow Logger" data logger are now listed and their alarms reach the plant's event list. A blue'Log logger gains a "String monitoring" section.
A component problem's "Confirmed by" now shows which measurement or device report opened the case, with an explanation of what it means, and a finding still being watched reads "Under observation". A "Reported operating states" section shows how long the machine spent throttling itself, capped, switched off or reporting a fault.
Linyang battery containers previously showed six temperature readings that no sensor takes, and modules 3 and 4 showed no temperature at all. Those readings have been removed, and cell temperatures are now filed under the right module.
A graph now zooms into the window dragged across it, a double-click or "Reset zoom" goes back, and "Enlarge graph" opens it full screen. The production day graph now draws in five-minute steps and refines to one minute once zoomed below six hours.
A plant held at its grid operator's or direct marketer's limit now reads as producing, not "Grid Shutdown" or "External Shutdown". One long curtailment no longer fills the event list with dozens of entries.