Huawei SUN2000 inverters now report phase-to-neutral voltages
AC voltages of Huawei SUN2000 inverters of the 60KTL, 185KTL and 215KTL families read through a Huawei SmartLogger no longer show line-to-line values under the phase names. The values now shown are the phase-to-neutral voltages, which are lower than the figures shown before. Plants receive this with their next agent update.
Huawei SmartLoggers can now be set up as data loggers
A Huawei SmartLogger 1000, 3000 or 4000 on a plant's network now appears under "Possible loggers" on the "Dataflow" page and reads the inverters, strings and sensors behind it. Plants receive this with their next agent update.
Phoenix Contact PLCnext controllers now serve as data loggers
A Phoenix Contact PLCnext controller found on a plant's network can now be set up as a data logger under "Possible loggers" on the "Dataflow" page, reporting the active-power limits from the grid operator and the direct marketer every 30 seconds, in percent. Plants receive this with their next agent update.
A network device's own web page at a plant opens again, including over slow connections and on older equipment.
- A device's web page now loads properly even when it pulls in many pieces at once, including on older equipment.
- A device on a slow connection now gets 30 seconds to answer instead of 10 before the page gives up.
A Janitza meter set up through the guided logger setup now reports feed-in in the right direction, whichever way its current transformers are wired.
A power cap of 85 % or more no longer counts as curtailment
A plant held at a power cap of 85 % or higher previously counted as curtailed all day, which showed curtailment losses that did not exist and skewed its performance ratio. Only a cap below 85 % now counts as curtailment. Plants receive this with their next agent update.
Plants without an irradiation sensor now get a performance ratio
The performance ratio of a plant that uses weather data instead of an on-site irradiation sensor now shows a figure where it showed none before, as the gaps between its 15-minute weather readings no longer count as missing data. Each plant receives this with its next on-site agent update. Plants receive this with their next agent update.
A data source that was unreachable when the on-site agent started now delivers its readings as soon as it answers again. A restart of the agent is no longer needed.
A cloudless-sky reference now shows what a plant would produce
A plant's production can now be compared, for every day, with the power and energy it would reach under a completely cloudless sky, in 15-minute steps, with and without the inverter peak cap. The same reference is rebuilt daily as a six-day outlook. Plants receive this with their next agent update.