2026 Nov5 Oct6 Sep8 Aug12 Jul6 2026
Mon, Nov 9 Agent Fix Major Alerts & events
A stopped unit's fault event previously stayed open for a day or more after the unit recovered. It now closes once the unit produces again. Plants receive this with their next agent update.
mirox-agents 3.2.251 – 3.2.256
Agent Improvements and fixes Alerts & events
mirox 2.15.830 – 2.15.857 mirox-agents 3.2.251 – 3.2.256
Fri, Nov 6 Agent Improvements and fixes Alerts & events
A device fault that stands for days is now raised once, not each night. A silent tracker now raises its no-communication event after 20 minutes, not 15. A condition the on-site agent retracted no longer announces a resolution. mirox 2.15.815 – 2.15.822
Tue, Nov 3 Agent Improvements and fixes Alerts & events
A plant no longer reads offline after a brief network link drop. A data logger's month-to-date yield no longer opens a false mismatch on a late step. A data logger is no longer alerted unreachable while the plant's network link is pending. A data logger outage is now reported once per episode. A battery historian's cell voltages are no longer withheld as "not fed". mirox-agents 3.2.244 – 3.2.246
Sun, Nov 1 Agent Improvements and fixes Alerts & events
In a plant's event list, DC measurement-defect descriptions now name the faulty DC reading. In a plant's event list, tracker silence and fault-stop events no longer repeat at night. In a plant's event list, a battery unit at rest no longer posts a state change every night. A data logger whose device list could not be read no longer reports its inverters as missing. In an export, a lifetime-energy total frozen at its maximum value is no longer shown. mirox-agents 3.2.235 – 3.2.238 mirox 2.15.778 – 2.15.779
Sat, Oct 31 Agent Improvements and fixes Alerts & events
On the plant's Events page, an open inverter alarm no longer closes and reopens with a reset start time when the on-site agent updates. A self-clearing inverter alarm no longer opens a device fault each night on the plant's Events page. On the plant's Events page, inverter alarm start times from a data logger that records local time now show in the plant's timezone. A mismatch event between a data logger's counter and its power reading no longer assumes the counter is wrong. A solar data logger's live data no longer stops for minutes while the on-site agent reads its history. On the plant's Events page, a warning event now names an inverter whose data read failed three times in a row. mirox 2.15.769 – 2.15.777 mirox-agents 3.2.232 – 3.2.234
Tue, Oct 27 Agent Fix Alerts & events
While a curtailment segment of a plant sat at a zero setpoint, the plant monitor previously marked its inverters as degraded. The inverters no longer open a degraded event. Plants receive this with their next agent update.
mirox-agents 3.2.194 – 3.2.196
Mon, Oct 26 Agent Feature Alerts & events
In a plant's event list, a no-communication summary now collects silent inverters, combiner boxes, turbines and battery storage into one notification, announced in 20-minute batches. It closes when every component reports again. Plants receive this with their next agent update.
mirox 2.15.704 – 2.15.777 mirox-agents 3.2.185 – 3.2.234
Agent Improvements and fixes Alerts & events
The plant's outage summary holds its notice for 30 minutes when a fault is reported before sunrise. mirox 2.15.704 – 2.15.717 mirox-agents 3.2.185 – 3.2.187
Mon, Oct 19 Agent Improvements and fixes Alerts & events
mirox 2.15.655 – 2.15.659
Thu, Oct 15 Agent Fix Alerts & events
A faulted inverter's outage now opens at once, instead of five minutes after the inverter stopped, and closes once the inverter produces again. The plant's outage summary names the inverters still down and counts the ones producing again. Plants receive this with their next agent update.
mirox 2.15.632 – 2.15.652 mirox-agents 3.2.153 – 3.2.161
Thu, Sep 24 Agent Improvements and fixes Alerts & events
mirox-agents 3.2.120 – 3.2.123 mirox 2.15.570 – 2.15.571
Mon, Sep 21 Agent Improvements and fixes Alerts & events
A combiner box that reports zero power against its own live readings no longer opens an outage. A silent inverter now opens a plant alarm after 12 hours. Two data loggers can now be added, reading combiner boxes, strings, the grid meter, irradiation and temperature sensors, and curtailment limits. A plant-wide grid trip is no longer recorded as a device fault. Event times from the data logger are no longer off by the timezone offset. mirox 2.15.539 – 2.15.552 mirox-agents 3.2.102 – 3.2.112
Sun, Sep 20 Agent Fix Alerts & events
A closed outage previously named only the components that recovered last — 7 of 17 silent inverters — and now lists the whole incident. A device fault no longer reopens once the device has withdrawn every fault code, and no longer reads "Live" after an outage takes it over. Plants receive this with their next agent update.
mirox 2.15.536 – 2.15.538 mirox-agents 3.2.97
Wed, Sep 9 Agent Improvements and fixes Alerts & events
An alarm raised by an inverter no longer closes just because part of its alarm list could not be read. A fault reported by an inverter no longer closes on its own after the on-site data collection restarts. A low-insulation warning no longer stays shown as active after the inverter has withdrawn it. A battery unit read by a second data logger no longer keeps the make and model of the previous one. The grid operator's ceilings on a battery storage's charging and discharging now appear on the plant's "Control Units" tab. Wind and battery plants now receive the site's weather data — temperature, wind, precipitation, snow and irradiation. mirox-agents 3.2.53 – 3.2.66 mirox 2.15.457 – 2.15.467
Tue, Sep 8 Agent Fix Alerts & events
A plant no longer opens an "Inverter device fault" when its data logger reports it cannot read an inverter and no readings arrive. A low-priority "Logger cannot reach inverter" entry opens instead and becomes "Inverter not communicating" after an hour of daylight, and plants receive this with their next agent update.
mirox 2.15.447 – 2.15.456 mirox-agents 3.2.50 – 3.2.51
Fri, Sep 4 Agent Improvements and fixes Alerts & events
A daylight reading an irradiation sensor cannot physically deliver is now refused, and inverters are no longer declared in outage against it. A plant's total feed-in energy is published again after an inverter has been replaced, or after the on-site data collection restarted. mirox-agents 3.2.14 – 3.2.23
Thu, Sep 3 Agent Improvements and fixes Alerts & events
An emergency stop, a device fault or a latched arc fault no longer clears itself while the inverter is still reporting it. Sungrow fan messages now appear as warnings rather than faults, as Sungrow itself rates them. Measurements taken while the plant cannot reach Mirox are now stored and sent on once the connection returns. An inverter that keeps falling back into the same reported state keeps one open entry, and every recurrence is counted. An alarm an inverter first reported as a warning and then as a fault now shows the more serious of the two. mirox 2.15.407 – 2.15.419 mirox-agents 3.2.4 – 3.2.12
Tue, Sep 1 Agent Fix Alerts & events
A plant held at its grid operator's or direct marketer's limit now reads as producing, not "Grid Shutdown" or "External Shutdown". One long curtailment no longer fills the event list with dozens of entries.
mirox-agents 3.1.445 – 3.1.446
Jump to month