November 20266

Web appImprovements and fixesAlerts & events

Condition events show how often the on-site agent raised them, and the plant monitor's "Service" tab folds a VPN or network outage into one row.

  • In a plant's "Events" list, a condition now shows how many times the on-site agent raised it.
  • A plant's VPN or its own network being offline now appears in the plant monitor's "Service" tab as one row for its data loggers.
  • In a plant's event dialog, the history distinguishes a recurrence closed by the on-site agent from a manual reopen.
  • In a plant's "Events" list, a failed surge protector or a fan, heater or cooling pump now raises a condition with its own label.
  • A device-fault event in a plant's "Events" list no longer keeps a stale raise count in its description after its reasoning changes.
mirox 2.15.815 – 2.15.822
AgentImprovements and fixesAlerts & events

False offline and unreachable alerts, false fault events and false data holds no longer fire on loggers, inverters and battery historians. An inverter fault that re-raises after its first raise now opens its fault event again.

  • A plant no longer reads offline after a brief network link drop.
  • A data logger's month-to-date yield no longer opens a false mismatch on a late step.
  • A data logger is no longer alerted unreachable while the plant's network link is pending.
  • A data logger outage is now reported once per episode.
  • A battery historian's cell voltages are no longer withheld as "not fed".
mirox-agents 3.2.244 – 3.2.246
AgentImprovements and fixesAlerts & events

In a plant's event list, DC measurement-defect, tracker and battery events no longer repeat. In an export, frozen lifetime-energy totals are not shown.

  • In a plant's event list, DC measurement-defect descriptions now name the faulty DC reading.
  • In a plant's event list, tracker silence and fault-stop events no longer repeat at night.
  • In a plant's event list, a battery unit at rest no longer posts a state change every night.
  • A data logger whose device list could not be read no longer reports its inverters as missing.
  • In an export, a lifetime-energy total frozen at its maximum value is no longer shown.
mirox-agents 3.2.235 – 3.2.238mirox 2.15.778 – 2.15.779

October 202619

AgentImprovements and fixesAlerts & events

An open inverter alarm on the plant's Events page keeps its start time when the on-site agent updates. A self-clearing inverter alarm no longer opens a device fault each night.

  • On the plant's Events page, an open inverter alarm no longer closes and reopens with a reset start time when the on-site agent updates.
  • A self-clearing inverter alarm no longer opens a device fault each night on the plant's Events page.
  • On the plant's Events page, inverter alarm start times from a data logger that records local time now show in the plant's timezone.
  • A mismatch event between a data logger's counter and its power reading no longer assumes the counter is wrong.
  • A solar data logger's live data no longer stops for minutes while the on-site agent reads its history.
  • On the plant's Events page, a warning event now names an inverter whose data read failed three times in a row.
mirox 2.15.769 – 2.15.777mirox-agents 3.2.232 – 3.2.234
Web appFeatureMajorAlerts & events

A battery unit not following its dispatch order raises an event

A battery unit idle or moving against its dispatch order for 15 minutes now raises an event on the plant's "Events" page. The event closes only when the unit or the storage as a whole follows an order again, or when its own fault stop, safety alarm or silence takes over.

mirox 2.15.757 – 2.15.768
Web appFeatureAlerts & events

Events in the plant monitor can now be acknowledged

In the plant monitor, an event can now be acknowledged for up to 14 days or until a chosen day. A plant whose events are all acknowledged but not all on a ticket is marked with a crossed bell.

mirox 2.15.718 – 2.15.735
AgentFixAlerts & events

A curtailed segment no longer marks its inverters as degraded

While a curtailment segment of a plant sat at a zero setpoint, the plant monitor previously marked its inverters as degraded. The inverters no longer open a degraded event. Plants receive this with their next agent update.

mirox-agents 3.2.194 – 3.2.196
AgentFeatureAlerts & events

A no-communication summary groups silent inverters and combiner boxes

In a plant's event list, a no-communication summary now collects silent inverters, combiner boxes, turbines and battery storage into one notification, announced in 20-minute batches. It closes when every component reports again. Plants receive this with their next agent update.

mirox 2.15.704 – 2.15.777mirox-agents 3.2.185 – 3.2.234
Web appFeatureMajorAlerts & events

A plant's "Events" page now lists every event as a table

The plant menu's "Events" page now replaces "Activity" under "Core Data". It lists every event of the plant as a table, open ones on top, with Source and Component header filters and a search box.

mirox 2.15.655 – 2.15.659
Web appFeatureMajorAlerts & events

A plant's events can now be closed, reported or escalated by hand

In a plant's event dialog, an event can now be closed, reported, or escalated by a job operator or technical operations manager. An open inverter or combiner box no-communication event can be escalated to an outage, with a notification naming who escalated it and the comment.

mirox 2.15.655 – 2.15.659
AgentFixAlerts & events

A faulted inverter's outage now opens at once

A faulted inverter's outage now opens at once, instead of five minutes after the inverter stopped, and closes once the inverter produces again. The plant's outage summary names the inverters still down and counts the ones producing again. Plants receive this with their next agent update.

mirox 2.15.632 – 2.15.652mirox-agents 3.2.153 – 3.2.161
Web appImprovements and fixesAlerts & events

Outage notices for a shared plant now reach every cooperation partner through its own marketer connection. Outage alert e-mails are no longer sent blank.

  • The assistant in the "Alarm Manager" rule editor now covers receivers, templates, the outage report and the direct marketer.
  • The "Alarm Manager" template builder previews the e-mail as it will be sent.
  • The stored-login shield no longer shows for a user name without a password on the networking devices table.
  • On a mobile-width page, assistant chat transcripts are reachable again under the auto-hiding navbar.
mirox 2.15.622 – 2.15.626
Web appFeatureAlerts & events

Webhook receivers now always send with an organization template

In the "Alarm Manager," a webhook receiver now always sends with one of the organization's templates. The receiver dialog lists the organization's templates, with the ready-made examples under "Templates".

mirox 2.15.620 – 2.15.621
Web appImprovements and fixesAlerts & events

The "Alarm Manager" no longer offers an acknowledge action; alerts open and close by the plant's state alone.

  • The "Alarm Manager" alert's detail page now shows who was notified.
  • Plant sum and per-inverter rules no longer fail to save in the "Alarm Manager" when the outage report is off.
  • The support composer takes a pasted screenshot as an inline image.
  • The support ticket list shows the plant in a sortable column.
  • The notification bell's list no longer leaves the page frozen when an alert in it is opened.
mirox 2.15.620 – 2.15.621
Web appFeatureMajorAlerts & events

The alert rule now carries the outage report

An alert rule now carries the outage report, with the direct marketer connection's one read-only receiver in the "Alarm Manager". The alert's "Deliveries" list shows each receiver at the outage's start, renewal and end.

mirox 2.15.619
Read more in the documentationAlerts and notifications
Web appFeatureMajorAlerts & events

A Modbus reader can be added with its own alarm signals

A Modbus reader can now be added as a data logger with its own alarm signals. Each signal has a level, a mode, and a minimum duration before it raises an alarm, and the plant's "Alarm system" page shows its state and its history.

mirox 2.15.600 – 2.15.606
Web appFeatureMajorAlerts & events

Turbines and battery units now raise health alarms

On the plant monitor, each turbine and battery unit now shows its health — fault, no communication, or paused — with a dialog naming why a unit is paused and since when. A unit safety alarm opens a notification linking to the unit's page, and the alarm is not silenced during a storm.