Inverters now show what they report about themselves: "Stopped by command" when one was switched off, "Protective stop" when its protection tripped, and "Device fault" when the machine reports a fault the measurements cannot show. The maker's own wording and how often it was raised are shown alongside.
The "Reduced output" flag no longer stays on a recovered component.
A device-reported thermal or insulation fault now confirms its event within 15 minutes, and a changed alarm count appears on the event within 30 minutes.
A string behind a data logger now reports its negative current when it back-feeds.
That quarter-hour's feed-in energy no longer drops from the Marktprämie after a restart inside a quarter-hour.
The status code an inverter reports about itself now opens an event when the device was stopped by command, tripped on its protection, raised a safety alarm or is throttling itself back. The health column shows "Stopped by command" and "Protective stop", and every code one inverter reports is held in a single event.
Alarms that NR Electric converters and Linyang battery containers raise about themselves now appear in the plant's event list, and an alarm closes again as soon as the device clears it. Each alarm shows how serious it is, and a Linyang alarm names the racks affected. Plants receive this with their next agent update.
An inverter at full output but showing wear is now flagged with "Elevated temperature", "Insulation weakening", "Phase imbalance" or "Efficiency declining". Each problem is marked on the component and listed separately.
Each inverter in the monitor's connection list now leads with the reason it cannot be reached: an open outage on the network device its data logger sits behind, naming that logger. Such an inverter counts as a connection issue at once, instead of only after an hour without a signal.
A plant's open-event count no longer adds the grouping alert on top of the dead components themselves: twelve dead inverters read as twelve.
Every event in a plant's activity list, dialogs and tickets now shows its name in the user's language instead of an untranslated one.
The month chart no longer marks a day as a connection outage when the plant produced right through a brief drop, or before monitoring began.
A Solar-Log logger can now be stopped, under its settings, from reporting a feed-in meter another source already reads, which counted grid power twice.
In the API, the site list can be narrowed by portfolio and type, both comma-separated, with the total and the paging following the filter.
"Reachable subnets" now shows where two plants' networks overlap, not only where they are identical, and lets the plant serving the shared addresses be chosen.
On a per-Wp day graph, the reference curve now follows the selected components, so an east-west plant shows both of its peaks.
The sign-in page now states how long the pause after repeated failed sign-ins lasts, and that changing the password does not end it early.
An irradiation sensor is now flagged when it reads zero while a neighbouring sensor or the plant's own production shows the sun is up. A confirmed defect also sends a notification.
A "Status" column on the monitor page shows a green checkmark when all is well, otherwise how many problems are open and how serious they are. Selecting it opens "Active events": everything still going on at that plant, grouped by type, each row linking to the part it concerns.
A plant that goes offline now raises one alert instead of two or none, and the alert closes only once the whole plant is reachable again. Alerts for devices that drop out in the same moment are held back, and plants receive this with their next agent update.