Skip to content

Changelog

Every change to Mirox, grouped by month. Filter by group or by kind of change.

Clear filters

November 20261

AgentFixMajorProduction & yield

The month-to-date yield no longer counts the previous day twice

A solar data logger's month-to-date yield previously counted the previous day's production again on the first day of a new month, inflating the lifetime energy sum. The repeated production is no longer published, and figures already issued keep their value. Plants receive this with their next agent update.

mirox-agents 3.2.244 – 3.2.246

October 20264

AgentFeatureMajorProduction & yield

A wind plant's expected production is now computed per turbine

A wind plant's expected production is now computed per turbine from the plant's measured weather, each turbine's power curve and hub height, and the air density. Plants receive this with their next agent update.

mirox 2.15.660 – 2.15.664mirox-agents 3.2.166 – 3.2.167

September 20262

AgentFixMajorProduction & yield

Wind and battery plants are no longer measured as solar plants

A plant set up as a wind plant or a standalone battery plant is no longer measured as if it had panels: it no longer shows an expected-production curve, a clear-sky reference, a performance ratio or curtailment figures. Solar plants are unchanged, and plants receive this with their next agent update.

mirox 2.15.428 – 2.15.442mirox-agents 3.2.32 – 3.2.41

August 20266

AgentFixProduction & yield

The performance ratio now comes from the inverters' own output

Wherever every inverter a plant expects has reported, the performance ratio now comes from what those inverters produced, not from the feed-in meter. Losses in the meter and the lines no longer count against it. Plants receive this with their next agent update.

mirox 2.15.376 – 2.15.393mirox-agents 3.1.435 – 3.1.442
AgentFixProduction & yield

A failed grid meter no longer hides curtailed minutes

The performance ratio is no longer flattered at a plant whose grid meter cannot be reached. Minutes the plant spent held down at the grid operator's limit are now left out, even without a reading from that meter, instead of counting as clean production. Plants receive this with their next agent update.

mirox-agents 3.1.422 – 3.1.433
AgentFixMajorProduction & yield

Expected production at capped plants no longer reads too low

The expected-production curve read too low at plants whose output is capped, sitting well below the cap on bright days. It now follows the cap itself, and expected production on a bright day matches what the plant is allowed to deliver. Plants receive this with their next agent update.

mirox-agents 3.1.278 – 3.1.296mirox 2.15.198 – 2.15.213
AgentImprovements and fixesProduction & yield

An inverter whose energy counter stalls no longer lowers a Fronius plant's energy, and editing a data logger no longer splits other loggers' inverter history.

  • At Fronius plants, an inverter whose lifetime energy total stops advancing no longer lowers the plant's energy, its production being worked out from its power.
  • Adding or editing a data logger no longer causes another logger's Huawei or Sungrow inverters to appear as new components with their history split.
mirox 2.15.190 – 2.15.197mirox-agents 3.1.259 – 3.1.276
AgentFixMajorProduction & yield

Curtailed minutes no longer count against the performance ratio

The performance ratio read too low at plants that were curtailed, and the expected production scaled from it was too low as well. Both are correct from this release, which plants receive with their next agent update. Plants receive this with their next agent update.

mirox-agents 3.1.214

July 20263

June 20269

May 20264

January 20263