Skip to content

Changelog

Every change to Mirox, grouped by month. Filter by group or by kind of change.

Clear filters

October 20261

Web appFeatureData collection

Sensors and feed-in meters show their logger and data state

On the plant's components page, in its sensor and meter tabs, each irradiation sensor and feed-in meter now shows which data logger serves it, its data state and its last data time. A logger filter narrows the table.

mirox 2.15.736 – 2.15.754

September 20262

Web appFeatureMajorData collection

A plant's history now imports from its previous monitoring system

The "Import" tab on a plant's "Dataflow" page now takes the ZIP archive from the plant's previous monitoring system and matches its devices to components by serial number or name. The import runs day by day and can be paused, stopped, or have what it wrote deleted.

mirox 2.15.420 – 2.15.564
Web appFeatureMajorData collection

The wizard now adds SMA Data Manager and Sungrow loggers

Devices behind an "SMA Data Manager / Power Manager" or "Sungrow Logger" data logger are now listed and their alarms reach the plant's event list. A blue'Log logger gains a "String monitoring" section.

mirox 2.15.397 – 2.15.406
Read more in the documentationData loggers

August 20263

Web appImprovements and fixesData collection

Adding a Phoenix Contact or Huawei data logger works again, instead of being refused the moment it is saved. A device's web page opened through remote access no longer loops endlessly or arrives as a file download.

  • Adding a Phoenix Contact or Huawei data logger no longer fails the moment it is saved.
  • A device's web page opened through remote access no longer loops endlessly or arrives as a file download.
  • The assistant now says when web search or document reading is unavailable, instead of answering from memory.
  • The name "MCP Server Authentication" is reserved for the assistant's own token and is refused when an access token is created.
  • The "Battery storage present" switch in a plant's master data now shows in the user's language.
mirox 2.15.243 – 2.15.252
Read more in the documentationData loggersProxy
Web appFeatureData collection

A data logger's settings can now be edited after it is added

The "Edit logger" dialog now has a "Configuration" tab. There, the options a data logger offers and the "Serial / metric id prefix" its components are identified by can be changed without deleting and re-adding the logger, and "Apply changes" sends them to the plant.

mirox 2.15.185 – 2.15.189
Read more in the documentationData loggers
Web appImprovements and fixesData collection

Each value read from a data logger can now be given its own factor and limits.

  • Under "Advanced settings", a factor and a high and low limit can be set for each value read from a data logger.
  • Inverters, combiner boxes and strings that have never sent a measurement are now counted separately, no longer as producing.
  • An inverter, combiner box, irradiation sensor or feed-in meter added by hand can now be deleted from its table, after a confirmation.
mirox 2.15.176 – 2.15.184
Read more in the documentationData loggers

July 20264

Web appFeatureData collection

A Huawei SmartLogger can now be added without storing its login

A Huawei SmartLogger can now be added without storing its login, since most readings come in over Modbus TCP rather than the web interface. A check then reports whether Modbus worked, is switched off or not permitted, or whether RS485 address conflicts hide inverters, naming the serial numbers it could not reach.

mirox 2.15.111 – 2.15.125
Web appImprovements and fixesData collection

A data logger's own web interface and its stored login now open straight from a plant's logger list.

  • A plant's data logger list now has a "Proxy" column that opens the logger's own web interface from its row.
  • In the stored-login dialog, the user name or the password can now be copied with one click.
  • On a plant with more than 100 network devices, a device's proxy link opens the device's own interface again instead of a wrong address.
  • After two-factor authentication is switched on, the proxy links in the network device and data logger tables appear at once, without a page reload.
mirox 2.15.111 – 2.15.125
Web appImprovements and fixesData collection

Data logger setup now shows which of the devices found still need a login.

  • A device that still needs a login is now marked "Password missing", and the key icon stores that login without a test read.
  • When a logger is not detected or its test read keeps failing, "Request logger support" sends a support request with its details filled in.
  • A plant's setup progress now has a fifth step, "Park data": peak power, inverter limit, coordinates and the twelve monthly performance-ratio targets.
  • When a direct VPN is added, "Mirox as Server" and "Mirox as Client" now explain their advantages and which one is recommended.
  • A component that produced earlier and then stopped no longer appears under "Probably not connected", nor does one on a plant commissioned hours ago.
mirox 2.15.89 – 2.15.96
Web appFeatureData collection

A Meteocontrol blue'Log data logger can now be added to a plant

A Meteocontrol blue'Log data logger can now be added to a plant, signed in with the password used on the device. Its devices and channels appear by name, and standard sensor channels come already recognised, needing only "Track this value".

mirox 2.15.80 – 2.15.88

June 20264

Web appImprovements and fixesData collection

A data logger's value mapping can now be corrected after setup through "Edit metrics". Strings on several selected inverters can now be edited in one step on a plant's components page.

  • Newly detected components show "Collecting data…" for their first two hours.
  • A plant's pages no longer show the on-site agent as not responding right after a configuration change restarts it.
  • A plant's solar analysis page no longer shows a clear-day count larger than the days its inverters have been reporting.
  • The mapping of an irradiation sensor on a data logger now records whether it measures horizontal or module-level.
mirox 2.14.133 – 2.14.136
Read more in the documentationData loggersComponents
Web appImprovements and fixesData collection

Agent-started wizard runs can be stopped, unresponsive runs end as failed after 30 minutes, and the agent configuration tab leaves the data-flow page.

  • A wizard run started by the on-site agent can be stopped by anyone who can see it.
  • A run that stops responding no longer sits on waiting and is marked failed after 30 minutes.
  • The plant's data-flow page no longer shows the agent configuration tab to organization admins and moderators.
mirox 2.14.26 – 2.14.37
Web appFeatureData collection

QReader data loggers can now be set up by mapping their values

A QReader data logger can now be set up by mapping its values. The "Map values" step lists every value the device sends for matching to a known measurement, and the "Dry run" step then shows which measurements the mapping produces before saving.

mirox 2.14.18 – 2.14.25
Read more in the documentationData loggers

May 20264

April 20263

January 20265