October 202610

Web appFeatureMajorAlerts & events

A battery unit not following its dispatch order raises an event

A battery unit idle or moving against its dispatch order for 15 minutes now raises an event on the plant's "Events" page. The event closes only when the unit or the storage as a whole follows an order again, or when its own fault stop, safety alarm or silence takes over.

mirox 2.15.757 – 2.15.768
Web appFeatureAlerts & events

Events in the plant monitor can now be acknowledged

In the plant monitor, an event can now be acknowledged for up to 14 days or until a chosen day. A plant whose events are all acknowledged but not all on a ticket is marked with a crossed bell.

mirox 2.15.718 – 2.15.735
Web appFeatureMajorAlerts & events

A plant's "Events" page now lists every event as a table

The plant menu's "Events" page now replaces "Activity" under "Core Data". It lists every event of the plant as a table, open ones on top, with Source and Component header filters and a search box.

mirox 2.15.655 – 2.15.659
Web appFeatureMajorAlerts & events

A plant's events can now be closed, reported or escalated by hand

In a plant's event dialog, an event can now be closed, reported, or escalated by a job operator or technical operations manager. An open inverter or combiner box no-communication event can be escalated to an outage, with a notification naming who escalated it and the comment.

mirox 2.15.655 – 2.15.659
Web appFeatureAlerts & events

Webhook receivers now always send with an organization template

In the "Alarm Manager," a webhook receiver now always sends with one of the organization's templates. The receiver dialog lists the organization's templates, with the ready-made examples under "Templates".

mirox 2.15.620 – 2.15.621
Web appFeatureMajorAlerts & events

The alert rule now carries the outage report

An alert rule now carries the outage report, with the direct marketer connection's one read-only receiver in the "Alarm Manager". The alert's "Deliveries" list shows each receiver at the outage's start, renewal and end.

mirox 2.15.619
Read more in the documentationAlerts and notifications
Web appFeatureMajorAlerts & events

A Modbus reader can be added with its own alarm signals

A Modbus reader can now be added as a data logger with its own alarm signals. Each signal has a level, a mode, and a minimum duration before it raises an alarm, and the plant's "Alarm system" page shows its state and its history.

mirox 2.15.600 – 2.15.606
Web appFeatureMajorAlerts & events

Turbines and battery units now raise health alarms

On the plant monitor, each turbine and battery unit now shows its health — fault, no communication, or paused — with a dialog naming why a unit is paused and since when. A unit safety alarm opens a notification linking to the unit's page, and the alarm is not silenced during a storm.

mirox 2.15.597 – 2.15.599

September 20263

Web appFeatureMajorAlerts & events

A plant with an alarm system now has an "Alarm system" page

A plant with an alarm system now has an "Alarm system" page, showing each contact's state, its history over 24 hours, 7 or 30 days, and the alarms raised. The intrusion panel and the communication cabinet's UPS, heating and main switch open a plant event while a contact stands and close it when it clears.

mirox 2.15.468 – 2.15.483
Read more in the documentationAlarmData loggers
Web appFeatureMajorAlerts & events

Station icons on the analysis page now count inverters

On a plant's analysis page, the icons on each station row now count inverters rather than items: one blue wrench for each inverter with open service work. An icon opens a list of those inverters with everything open on each, each entry linking to its inverter.

mirox 2.15.407 – 2.15.419
Read more in the documentationInverter events
Web appFeatureAlerts & events

Component problems now show what confirmed them and how devices ran

A component problem's "Confirmed by" now shows which measurement or device report opened the case, with an explanation of what it means, and a finding still being watched reads "Under observation". A "Reported operating states" section shows how long the machine spent throttling itself, capped, switched off or reporting a fault.

mirox 2.15.397 – 2.15.406
Read more in the documentationEventsInverter status codes