The inverter availability figure used for the technical report and the data export misread days without enough sunlight: such a day produced no availability value at all. These days now count as fully available, and only intervals with enough sunlight and no inverter output reduce the figure.
On a plant's components page, each data logger in the data logger tab now shows whether the on-site agent is collecting from it, with a "Pause" menu. You pause collection for 15 minutes up to 24 hours, for example during maintenance; it resumes by itself, or earlier with "Resume".
On a plant's components page, the data logger tab has a new "Add Logger" button. You choose the logger type, then enter its name, address, polling interval, credentials and the settings that belong to that type. The new data logger appears in the list with the status initializing.
The dashboard's production, shutdown and loss tiles show the EUR value as the main figure; a switch beside the time selector puts energy first instead.
The dashboard's energy bars set a negative daily value to 0 and offset it against the next day.
The analysis page's power graph starts with the "String Sum" line switched off; you can switch it on in the graph's legend.
A plant's components page has a new "Data Logger" tab. It lists the plant's data loggers with their communication status and address, and a logger's details show its source, serial number, state and connection settings.
The analysis page's daily energy bars and energy totals no longer show spikes when an inverter's, combiner box's or string's energy counter briefly reads zero.
A negative daily energy bar on the analysis page is set to 0 and offset against the next day.
On the analysis page, "Select Columns" sets which columns the inverter, combiner box and string tables show.
The components page's inverter, combiner box and string lists flag a component without data for 1 year.
A plant's component totals and inverter power count components that were never marked as hidden again.
The "Report" entry in a plant's menu is greyed out and cannot be opened.
On plants with a Huawei data logger, the on-site agent now reads string voltages and currents for up to 18 strings per inverter, up from 12. Larger inverters such as the SUN2000-185KTL get values for strings 13 to 18. Your plants receive this with their next agent update.
Inverters count as communicating when they delivered data within the last hour; the production page's inverter table shows when each was last seen.
The production page's inverter table shows data availability in daylight as a percentage ring; a reading counts only when power is above 0 W.
You can mark an inverter as hidden in its details; hidden components and everything beneath them leave plant totals, the analysis table and reports.
The components page flags inverters without data for 1 hour and combiner boxes and strings without data for 25 hours.
The monitor opens an overview of a plant's data loggers with status, and the production page shows the data logger each inverter reports through.
A plant's production status now distinguishes offline, unknown and overproduction, and an info icon in the dashboard and the monitor explains each status.
The production and analysis graphs hatch periods with snow on the ground and name it in the tooltip.
The analysis page's tables add "Energy Loss" and "Efficiency" columns, and "Energy reference", formerly "Digital Twin", shows measured divided by simulated energy.
On plants with a Sungrow data logger, each inverter's values are now assigned by the device list the logger itself reports. Before, inverters were numbered by their position in the logger's overview, so an inverter's detailed and string values could come from a different inverter or be missing. Your plants receive this with their next agent update.