On a solar plant's analysis page, the "Park control" tab now shows the grid operator's and the direct marketer's power limit per segment, in percent or watts, with a week or month line graph.
A curtailment settlement month is no longer finalized while satellite data is still missing. It is rebuilt once more if that data arrives up to 14 days after the month's deadline. Plants receive this with their next agent update.
Curtailment figures now include the plant controller's power cap and the direct marketer's active-power setpoint. The curtailment figure no longer reads too low where either ran. Plants receive this with their next agent update.
Curtailment settlement and lost energy no longer read too low for a period that started after a quiet stretch. The current and previous month are recalculated on the next run, and older months keep their value. Plants receive this with their next agent update.
The raw curtailment columns of a wind plant settled as "Spitz Wind (power curve)", "Spitz Wind light (reference wind speed)" or "Pauschal Wind (flat rate)" no longer come back empty in exports. They now carry the value.
The limit a direct marketer states was shown twice, once against the plant controller's own rating. It is now a single figure against the plant's own setpoint, and the plant's curtailed energy is corrected. Plants receive this with their next agent update.
Curtailment and compensation shown close to live no longer show impossible values. A plant whose reference days all fail the plausibility check shows no close-to-live figure, and issued figures keep their value. Plants receive this with their next agent update.
A wind plant's "Turbines" page now shows the energy lost to the grid operator, the direct marketer, environmental limits, stop commands and turbine faults. The losses are drawn as stacked areas on the day graph, as segments of the daily, weekly and monthly bars, and as a "Lost in total" figure.
The dashboard's curtailment chart and cards now show the same settled figures as a plant's production page, with quarter-hours not yet settled filled in close to live. Curtailment from before June 2026 is no longer shown on the dashboard because it came from an older calculation, while figures already issued keep their value.
Curtailment and compensation shown before the settlement at plants with battery storage now come from what the inverters produced, not from the feed-in meter behind the battery. They fall wherever the plant was charging or discharging while a limit was in force, and plants receive this with their next agent update. Plants receive this with their next agent update.
Curtailment losses previously read too high for any quarter-hour in which the on-site data collection paused: those minutes counted as zero production. Those minutes now count at the rate the measured minutes around them show, and lost energy and compensation fall for such quarter-hours.