Skip to content

Changelog

Every change to Mirox, grouped by month. Filter by group or by kind of change.

Clear filters

November 20261

Web appImprovements and fixesAlerts & events

Condition events show how often the on-site agent raised them, and the plant monitor's "Service" tab folds a VPN or network outage into one row.

  • In a plant's "Events" list, a condition now shows how many times the on-site agent raised it.
  • A plant's VPN or its own network being offline now appears in the plant monitor's "Service" tab as one row for its data loggers.
  • In a plant's event dialog, the history distinguishes a recurrence closed by the on-site agent from a manual reopen.
  • In a plant's "Events" list, a failed surge protector or a fan, heater or cooling pump now raises a condition with its own label.
  • A device-fault event in a plant's "Events" list no longer keeps a stale raise count in its description after its reasoning changes.
mirox 2.15.815 – 2.15.822

October 202613

Web appFeatureMajorAlerts & events

A battery unit not following its dispatch order raises an event

A battery unit idle or moving against its dispatch order for 15 minutes now raises an event on the plant's "Events" page. The event closes only when the unit or the storage as a whole follows an order again, or when its own fault stop, safety alarm or silence takes over.

mirox 2.15.757 – 2.15.768
Web appFeatureAlerts & events

Events in the plant monitor can now be acknowledged

In the plant monitor, an event can now be acknowledged for up to 14 days or until a chosen day. A plant whose events are all acknowledged but not all on a ticket is marked with a crossed bell.

mirox 2.15.718 – 2.15.735
Web appFeatureMajorAlerts & events

A plant's "Events" page now lists every event as a table

The plant menu's "Events" page now replaces "Activity" under "Core Data". It lists every event of the plant as a table, open ones on top, with Source and Component header filters and a search box.

mirox 2.15.655 – 2.15.659
Web appFeatureMajorAlerts & events

A plant's events can now be closed, reported or escalated by hand

In a plant's event dialog, an event can now be closed, reported, or escalated by a job operator or technical operations manager. An open inverter or combiner box no-communication event can be escalated to an outage, with a notification naming who escalated it and the comment.

mirox 2.15.655 – 2.15.659
Web appImprovements and fixesAlerts & events

Outage notices for a shared plant now reach every cooperation partner through its own marketer connection. Outage alert e-mails are no longer sent blank.

  • The assistant in the "Alarm Manager" rule editor now covers receivers, templates, the outage report and the direct marketer.
  • The "Alarm Manager" template builder previews the e-mail as it will be sent.
  • The stored-login shield no longer shows for a user name without a password on the networking devices table.
  • On a mobile-width page, assistant chat transcripts are reachable again under the auto-hiding navbar.
mirox 2.15.622 – 2.15.626
Web appFeatureAlerts & events

Webhook receivers now always send with an organization template

In the "Alarm Manager," a webhook receiver now always sends with one of the organization's templates. The receiver dialog lists the organization's templates, with the ready-made examples under "Templates".

mirox 2.15.620 – 2.15.621
Web appImprovements and fixesAlerts & events

The "Alarm Manager" no longer offers an acknowledge action; alerts open and close by the plant's state alone.

  • The "Alarm Manager" alert's detail page now shows who was notified.
  • Plant sum and per-inverter rules no longer fail to save in the "Alarm Manager" when the outage report is off.
  • The support composer takes a pasted screenshot as an inline image.
  • The support ticket list shows the plant in a sortable column.
  • The notification bell's list no longer leaves the page frozen when an alert in it is opened.
mirox 2.15.620 – 2.15.621
Web appFeatureMajorAlerts & events

The alert rule now carries the outage report

An alert rule now carries the outage report, with the direct marketer connection's one read-only receiver in the "Alarm Manager". The alert's "Deliveries" list shows each receiver at the outage's start, renewal and end.

mirox 2.15.619
Read more in the documentationAlerts and notifications
Web appFeatureMajorAlerts & events

A Modbus reader can be added with its own alarm signals

A Modbus reader can now be added as a data logger with its own alarm signals. Each signal has a level, a mode, and a minimum duration before it raises an alarm, and the plant's "Alarm system" page shows its state and its history.

mirox 2.15.600 – 2.15.606
Web appFeatureMajorAlerts & events

Turbines and battery units now raise health alarms

On the plant monitor, each turbine and battery unit now shows its health — fault, no communication, or paused — with a dialog naming why a unit is paused and since when. A unit safety alarm opens a notification linking to the unit's page, and the alarm is not silenced during a storm.

mirox 2.15.597 – 2.15.599

September 20267

August 202611

July 202615

April 20261