The readiness timeline's official-price row no longer shows July as overdue. July's settlement now uses the official price, and issued figures keep their value.
The raw curtailment columns of a wind plant settled as "Spitz Wind (power curve)", "Spitz Wind light (reference wind speed)" or "Pauschal Wind (flat rate)" no longer come back empty in exports. They now carry the value.
An inverter that reports a fault no longer opens its outage only after a curtailment cap or low light has lifted. The event dialog shows which condition it overrode, with the maker's status and text.
The limit a direct marketer states was shown twice, once against the plant controller's own rating. It is now a single figure against the plant's own setpoint, and the plant's curtailed energy is corrected. Plants receive this with their next agent update.
Curtailment and compensation shown close to live no longer show impossible values. A plant whose reference days all fail the plausibility check shows no close-to-live figure, and issued figures keep their value. Plants receive this with their next agent update.
A combiner box behind a data logger previously showed a measured 0 W while its strings carried real current. A missing channel now shows nothing, and an explicit zero still reads as zero. Plants receive this with their next agent update.
In a plant's "Reports" page, the "Outage summary" table lists the month's inverter faults per inverter or per station, with events, duration and energy lost.
The "Outage summary" can show the revenue the lost production would have earned, for members with the accounting permission.
Reports can now be generated in six languages, with Spanish, French, Italian and Portuguese joining English and German.
The component-outage summary no longer marks each inverter's curve on the analysis graph or the production page.
The assistant no longer answers with incoherent text.
On the networking page, a web interface that was detected once is no longer removed when it is not detected again.
A closed outage previously named only the components that recovered last — 7 of 17 silent inverters — and now lists the whole incident. A device fault no longer reopens once the device has withdrawn every fault code, and no longer reads "Live" after an outage takes it over. Plants receive this with their next agent update.
A remote-access (VPN) share no longer closes by itself one hour after the technician's connection comes up. It stays available until the expiry chosen when sharing, or until it is revoked.
The embedded Grafana dashboards now pick up a member's changed role at the member's next sign-in to the dashboards instead of keeping the old role. An access update after a change in one organization now touches only that organization's portfolios and completes sooner.
Wind speed and wind gusts from the weather service were previously recorded in km/h under an m/s label, so the values shown read about 3.6 times too high. They are now recorded in m/s, and values recorded earlier keep the old figure.
Days that read tens of GWh too high or too low, after a turbine's history was read in again or after a turbine fell silent, now show what the turbines actually produced. The corrected figures appear in the day, week, month and year views and on the day power curve.
The dashboard's curtailment chart and cards now show the same settled figures as a plant's production page, with quarter-hours not yet settled filled in close to live. Curtailment from before June 2026 is no longer shown on the dashboard because it came from an older calculation, while figures already issued keep their value.
Curtailment and compensation shown before the settlement at plants with battery storage now come from what the inverters produced, not from the feed-in meter behind the battery. They fall wherever the plant was charging or discharging while a limit was in force, and plants receive this with their next agent update. Plants receive this with their next agent update.
A plant no longer opens an "Inverter device fault" when its data logger reports it cannot read an inverter and no readings arrive. A low-priority "Logger cannot reach inverter" entry opens instead and becomes "Inverter not communicating" after an hour of daylight, and plants receive this with their next agent update.
A plant's "Reports" page now assembles a report from chosen sections, with a preview and a PDF or JSON download.
The "Resources" tab on the organization page opens again where it lists a plant with wind turbines.
The monitor and dashboard plant lists now carry a "State" column — "Alert", "Warning", "Communication issue", "Disconnected", "Check" or "Inactive".
The "Turbines" page now shows each turbine's "Utilization (capacity factor)" and, where a datasheet is known, the maker's "Reference curve" with its "Validity band".
A plant set up as a wind plant or a standalone battery plant is no longer measured as if it had panels: it no longer shows an expected-production curve, a clear-sky reference, a performance ratio or curtailment figures. Solar plants are unchanged, and plants receive this with their next agent update.
Curtailment losses previously read too high for any quarter-hour in which the on-site data collection paused: those minutes counted as zero production. Those minutes now count at the rate the measured minutes around them show, and lost energy and compensation fall for such quarter-hours.
Linyang battery containers previously showed six temperature readings that no sensor takes, and modules 3 and 4 showed no temperature at all. Those readings have been removed, and cell temperatures are now filed under the right module.
A plant held at its grid operator's or direct marketer's limit now reads as producing, not "Grid Shutdown" or "External Shutdown". One long curtailment no longer fills the event list with dozens of entries.