A reading that briefly showed an energy counter at zero or a nonsense high value previously re-added the counter's total as new energy. Energy figures in graphs, reports, exports and the battery dashboard now cancel that reading against the next one, so the affected figures fall to what the plant actually produced.
The "Reports" page now offers a "Technical Report" template with the plant's master data, panel and inverter inventories, a performance ratio analysis by day and month, a metrics chapter, high-priority events and a glossary. The template's title page can be composed in the editor and matches the PDF and document exports.
A power quality analyzer can now be added as a feed-in meter and reads the grid, the PV feeder or the battery feeder. Plants receive this with their next agent update.